✨ New Arrivals Just Dropped!Explore
HomeStore

Server Technology, Inc C1W24VS-YBFA11A0

No images

Server Technology, Inc C1W24VS-YBFA11A0

Server Technology Switched PDU - 5.7kW, C1W24VS-YBFA11A0 - Switched - NEMA L21-20P - 24 x IEC 60320 C13, 1 x NEMA 5-20R - 208 V - Network (RJ-45) - Cabinet-mountable, Rack-mountable - Rack/Tower

The Server Technology® Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched Master" PDU can be connected to a Switched "Link"Â? PDU to extend the network access to the redundant or secondary power feed."

Server Technology Switched PDU - 5.7kW, C1W24VS-YBFA11A0 - Switched - NEMA L21-20P - 24 x IEC 60320 C13, 1 x NEMA 5-20R - 208 V - Network (RJ-45) - Cabinet-mountable, Rack-mountable - Rack/Tower

The Server Technology® Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched Master" PDU can be connected to a Switched "Link"Â? PDU to extend the network access to the redundant or secondary power feed."

$527.85

Original: $1,759.50

-70%
Server Technology, Inc C1W24VS-YBFA11A0

$1,759.50

$527.85

Description

Server Technology Switched PDU - 5.7kW, C1W24VS-YBFA11A0 - Switched - NEMA L21-20P - 24 x IEC 60320 C13, 1 x NEMA 5-20R - 208 V - Network (RJ-45) - Cabinet-mountable, Rack-mountable - Rack/Tower

The Server Technology® Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The Switched Master" PDU can be connected to a Switched "Link"Â? PDU to extend the network access to the redundant or secondary power feed."

Server Technology, Inc C1W24VS-YBFA11A0 | Google